Two Liquid Circuits, One Product Gas Line
Select equipment for details. Animated particles indicate flow direction; values show the current steady state.—
—
Class I gas quality · itemized inspection
GB 17820—2018 + GB/T 41328—2022. Retain the applicable scope and verification boundaries for each item.
| Quality Project | Simulation results | Natural gas category 1 / Biogas category 1 | Screening Results |
|---|
Gas concentration and heating value reference conditions: 20°C, 101.325 kPa; all components calculated on a dry basis. Dew point is calculated at the selected crossover absolute pressure. H₂, CO, NH₃, Hg, total chlorine, hydrocarbon dew point, siloxanes, particles/oil, etc., which are not calculated, should be confirmed according to applicable standards, receiving pipeline agreements, and measurements; model compliance does not imply permitted pipeline access.
Component Closed Item by Item
All gas volumes are unified to 0°C dry basis Nm³/h; reflux belongs to internal circulation and is not counted again in external output.
| Component | Raw Material | After stripping | Flash evaporation reflux¹ | Product | Water regeneration tail gas² | Raw desulfurization transfer³ | External Closing Difference |
|---|
¹ Flash vapor reflux has been iteratively solved within the absorber circulation and returned to the compressor inlet. ² This table shows the amount of feed components entering the tail gas; stripping air is added additionally and listed separately. ³ H₂S transfer is in gas-equivalent terms; sulfur actually enters S⁰ and sulfates, and gas volume is not conserved.
Final destination of sulfur · kg S/d
Final destination of methane · Nm³/d
Sulfur recovery, chemicals, and energy
Theoretical quantity and demonstration estimates are listed separately; CO₂ carbonation, actual emissions, and nutrient consumption are not considered.
| Material consumption / load | Calculated Value | Caliber |
|---|
Electric power distribution · kW
Compression is approximated based on isothermal efficiency; pumps based on pressure difference/efficiency; refrigeration based on the water-side sensible heat and COP. Automatic flow matching does not mean the existing pumps, towers, and refrigeration units can handle it. Cooling tower fans, heating regeneration, instrumentation control, and spare equipment are not considered.
How water temperature and circulation rate change the product
Fix the current gas source, pressure, and capacity, changing only one variable. The dashed line represents the mass limit of CO₂ ≤ 3%.
Water Temperature → Product CO₂
Liquid-to-Gas Ratio → Product CO₂
Sensitivity charts are used to show trends. Curves are based on the assumed mass transfer relationships on this page; actual packing height, gas-liquid distribution, solution salt content, and residual CO₂ in lean water may change the results.