Chintech Innovation · Process Lab ← Back to site All Simulations 中文 Handbook
CHINTECH / PROCESS LAB

Chelated Iron Desulfurization + Membrane Upgrading

Three-stage single-compressor process based on Evonik SEPURAN® Green · Biomethane quality screening

Single file · Offline operation

10,000–30,000 Nm³/d · CH₄ 60–70%

Steady-state model + process animation / 2026.10

Calculating baseline operating conditions...
Purified Gas Yield · Current Process
—
—
Product Methane / Carbon Dioxide
—
—
Dry Sulfur Production · Main Desulfurization by Complexed Iron
—
—
Power consumption accounted · Compression and auxiliaries
—
—

The same batch of raw material, two separation processes

Three-stage connection referenced from the official Evonik single-unit process; membrane area, pressure, and permeation parameters are assumptions for this page demonstration.

Three-Level Process
Retained gas / product Permeate gas / tail gas Reflux Gas Ferric complex solution circulation

Narrow screens can slide the flowchart left and right; click equipment to view calculation instructions.

Raw biogas ——— Chelated Iron Absorber H₂S → S⁰— Outlet H₂S Polishing / Pretreatment Dehydration / Oil / Siloxane — Membrane Inlet H₂S Main compression · cooling —— M1 / Main CO₂ Removal ———— M1 Permeate · Separate Line — M2 / product purification ——— Product / Delivery Outlet —— Analyzer / Off-spec Interlock Air Regenerator Fe²⁺→Fe³⁺ Lean Solution Circulation — Air in Separate Liquid Circuit Sulfur Separation S⁰ Filtration — Theoretical Dry Sulfur M3 / Methane Recovery —— Recycle Regulator —— Tail Gas → Treatment —— Tail Gas Treatment Required —

Two-stage / three-stage parameter comparison · Only increase or decrease the M3 branch.

Three-stage addition of M3 and medium-pressure reflux pressure regulating valve · shared single main unit

The two stages retain the original model’s low-pressure M1 permeate direct-to-exhaust structure, using the same M1/M2 area as the three-stage setup; the values here do not represent the performance of the selected Evonik R2X two-stage equipment.

Product composition · Dry basis volume fraction

The impact of the incoming gas flow under the current equipment capacity

Only change the inlet flow, keep equipment parameters fixed; this is not the manufacturer performance curve.

Cooperation

Need a custom simulation for your project?

This page is a public demo. We can build a tailored simulation model calibrated with your feed gas composition, operating conditions, and equipment parameters — for process evaluation, pre-commissioning trials, and operational optimization.